The Daxom 12kW electric boiler P1, P2 and P3 settings allow installers to select a maximum heating capacity on models equipped with three-level capacity control. The boiler can still modulate its output below the chosen limit to respond to heating demand.
What do P1, P2 and P3 mean on a Daxom 12kW boiler?
On applicable 12kW Daxom electric boilers, the three capacity settings correspond to one-third, two-thirds and full rated output:
| Boiler setting | Maximum heating capacity | Share of 12kW rating |
|---|---|---|
| P1 | 4kW | One-third |
| P2 | 8kW | Two-thirds |
| P3 | 12kW | Full capacity |
Important: P1, P2 and P3 establish an upper limit for heating output; they do not force the boiler to run continuously at exactly 4kW, 8kW or 12kW. Confirm that these settings apply to your particular boiler model in its installation and operating manual.
How do the power settings work with full modulation?
Daxom’s 12kW models are designed to modulate their heating output, with a stated modulation range down to approximately 2kW on relevant models. Modulation adjusts the heating power according to operating conditions, rather than keeping the boiler permanently at its maximum rated output.
For example, selecting P2 (8kW) means the boiler may use less power when heating demand is low, but its selected maximum heating capacity is 8kW. The actual delivered power depends on the boiler’s controls, water temperature and heating demand.
Example: choosing P1, P2 or P3 for a property
Consider a property with a calculated design heat loss of around 7kW. An installer may consider P2 on a compatible 12kW model because its 8kW maximum heating capacity exceeds that design figure. Whether that is the right setting also depends on warm-up requirements, system design and the appliance’s instructions.
- P1 – 4kW maximum: may be appropriate where the calculated central-heating demand is sufficiently low.
- P2 – 8kW maximum: may suit a heating system whose design requirement remains within that capacity.
- P3 – 12kW maximum: retains the full rated heating capacity when the installation requires it.
A lower P setting does not automatically reduce total energy consumption or guarantee lower bills. If a building needs a particular amount of heat, lowering the maximum output may mean the boiler runs for longer, or it may be unable to maintain the desired temperature during very cold weather.
What is the difference between a capacity limit and modulation?
Capacity limitation determines the highest heating power available under the selected setting. Modulation is the boiler’s automatic adjustment of output during operation within the permitted range.
These functions can work together: a suitable capacity ceiling may help manage peak heating demand, while modulation adjusts output in response to changing heating conditions. It is still essential to size the boiler correctly for the property’s heat loss and electrical installation.
Do P1, P2 and P3 affect the electric boiler’s hot water?
Do not assume that limiting the central-heating output also limits domestic hot-water operation in the same way on every Daxom boiler.
For example, the Daxom 12kW compact electric combi boiler (UKDAX-12EDM) provides instantaneous domestic hot water and may need its full rated 12kW output for that function. Models with integrated cylinders, such as the Daxom 12kW electric combi boiler with 50-litre cylinder (UKDAX-12EBM), operate differently because water is stored and heated in a cylinder.
Always refer to the Daxom boiler manuals and installation guidance to check the capacity-setting procedure and its effect on the specific appliance and domestic-hot-water mode.
Who should set the boiler’s maximum heating capacity?
The appropriate setting should be assessed during installation and commissioning by a suitably qualified professional. Key factors include:
- the building’s calculated design heat loss;
- radiator or underfloor-heating requirements;
- the available electrical supply and circuit design;
- the boiler model and manufacturer instructions;
- domestic hot-water demand, where applicable.
Our heat loss calculator can provide a starting point, but it is not a substitute for a proper installation assessment.
Daxom 12kW boiler settings: frequently asked questions
What does P1 mean on a Daxom 12kW boiler?
On models with the three-level capacity function, P1 sets the maximum heating capacity to one-third of 12kW, or 4kW.
What does P2 mean?
P2 sets the maximum heating capacity to two-thirds of 12kW, or 8kW, on applicable models.
What does P3 mean?
P3 allows the full 12kW maximum heating capacity on applicable 12kW models.
Does choosing P1 mean the boiler always consumes 4kW?
No. P1 is a maximum heating-capacity limit, not a fixed continuous electrical draw. The boiler can modulate output according to the operating conditions within its available range.
Does setting a boiler to P1 or P2 save electricity?
Not necessarily. A capacity limit changes the maximum rate at which heat can be delivered. Energy use depends primarily on heat loss, set temperatures, weather, controls and how long heating is required.
Can I change these settings myself?
Check the manual for your exact model. Capacity settings that affect system commissioning or electrical demand should be selected with advice from a suitably qualified installer.
Compare Daxom electric boiler options
Explore the 12kW compact electric combi boiler and the 12kW electric combi boiler with 50L cylinder, or view the full Daxom electric boiler range. For installation-specific advice, follow the documentation supplied with the boiler.